Exhaust unit Product List and Ranking from 6 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

Exhaust unit Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

  1. ニッタ クリーンエンジニアリング事業部 Osaka//others
  2. 日本エアーテック 本社 Tokyo//others
  3. 伸榮産業 本社、関東営業所 Osaka//others
  4. 4 多田製作所 Osaka//others
  5. 4 日本医化器械製作所 本社 Osaka//others

Exhaust unit Product ranking

Last Updated: Aggregation Period:Oct 08, 2025~Nov 04, 2025
This ranking is based on the number of page views on our site.

  1. Wall-mounted exhaust HEPA unit "NBU Series" ニッタ クリーンエンジニアリング事業部
  2. Package-type exhaust unit <negative pressure management> 日本エアーテック 本社
  3. Dust collection efficiency, over 99.99% for 0.3μm particles! 'Infection Control Unit' 多田製作所
  4. Simple Negative Pressure Device/Air Purifier Infection Control Exhaust Unit 'NEU-10' 日本医化器械製作所 本社
  5. 4 Simple Negative Pressure Device Exhaust Unit for Safely Exhausting Air from Hospital Rooms to the Outdoors 伸榮産業 本社、関東営業所

Exhaust unit Product List

1~8 item / All 8 items

Displayed results

Dust collection efficiency, over 99.99% for 0.3μm particles! 'Infection Control Unit'

Can be installed in patient rooms, examination rooms, break rooms, etc., to prevent hospital-acquired infections! Equipped with casters for easy mobility.

Tada Manufacturing's "Infection Control Unit" does not require special electrical work and can be used with a household power supply (AC100V). It is effective for preventing infections such as influenza and viruses. 【Features】 ■ Can be installed in hospital rooms to prevent hospital-acquired infections ■ Creates negative pressure in the room and exhausts air outdoors via ducts *Some models can also be circulation type ■ Exhaust air is sterilized with a HEPA filter ■ Can be easily installed in existing rooms ■ Equipped with casters for easy mobility 【Main Specifications】 Product Name: Infection Control Exhaust Unit Airflow: Maximum airflow 16m3/min Size: W850×D650×H1780mm *Excluding damper 【Filter Specifications】 ■ Dust collection efficiency: 99.99% or more for 0.3μm particles ■ Main Filter: HEPA filter (sterilizing enzyme filter) ■ Pre-filter: Non-woven fabric filter *For more details, please contact us or download the PDF.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simple Negative Pressure Device/Air Purifier Infection Control Exhaust Unit 'NEU-10'

For simple infection control in hospital rooms! An infection control exhaust unit that allows for HEPA filter lifespan management with a driving cumulative meter.

The "NEU-10" is an exhaust unit that can be installed in patient rooms for airborne infection cases. It is equipped with a high-performance filter (HEPA filter) and can operate with a standard grounded outlet, eliminating the need for special electrical work. When equipped with an optional circulating exhaust hood, it can also be used as an air purifier with a HEPA filter. 【Features】 ■ Built-in high-performance filter (HEPA filter) ■ Operates with a standard grounded outlet ■ No special electrical work required ■ Easy to move with casters ■ Includes anti-tipping brackets *For more details, please refer to the PDF document or feel free to contact us.

  • Drainage and ventilation equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Simple Negative Pressure Device Exhaust Unit for Safely Exhausting Air from Hospital Rooms to the Outdoors

Exhausting the air in the patient room through a HEPA filter to the outdoors, creating negative pressure.

Installed in patient rooms, examination rooms, waiting rooms, etc., it exhausts indoor air through a HEPA filter to the outside, reducing infection risk. It can also be used as an air purifier by exhausting clean air indoors.

  • Clean Room
  • Ventilation and smoke exhaust equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cleanroom product "Clean Exhaust Unit"

Lightweight and compact, it can be directly installed on dust generation areas! It reduces the air conditioning load in clean rooms.

The "Clean Exhaust Unit" is our original clean unit designed for incorporation into various types of equipment used in clean rooms, actively preventing dust generation. By changing the exhaust from machinery from outdoor discharge to indoor circulation, it reduces the air conditioning load of the clean room, leading to cost savings. 【Features】 ■ Reduction of CO2 emissions from the clean room ■ Lightweight and compact, can be directly mounted on dust-generating areas ■ No piping required, no vacuum blower needed ■ Low noise ■ Low cost *For more details, please refer to the PDF document or feel free to contact us.

  • Clean Room
  • Air conditioning equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cleanroom Exhaust Unit "CAP Series"

We offer 'HEPA filter specifications' and 'pre-filter specifications'! Full welded construction is also possible.

Introducing the exhaust unit for clean rooms from the CAP series. Manufacturing is possible with various materials. Full welded structures can also be made, and it is possible to accommodate requirements for airtightness needed for hazard countermeasures. We offer "HEPA filter specifications" and "pre-filter specifications." 【Features】 ■ Dedicated exhaust unit from the wall ■ Manufacturing is possible with various materials ■ Full welded structures can be made ■ It is possible to accommodate requirements for airtightness needed for hazard countermeasures *For more details, please refer to the PDF materials or feel free to contact us.

  • Clean Room

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Wall-mounted exhaust HEPA unit "NBU Series"

Reduction of scattering risk through cleaning! The visible outer surface is finished with #400 buffing, and it has passed airtightness testing (internal standards)!

The "NBU Series" is a wall-mounted exhaust HEPA unit with a fully welded structure made of SUS304 for the main unit and a lower suction section with a V-slit. The main unit features a flat panel structure with minimal unevenness. The HEPA filter can be replaced without directly touching it during the exchange, reducing the risk of contamination during cleaning. 【Features】 ■ Fully welded structure of the main unit made of SUS304 with a lower suction section V-slit ■ Compatible with HEPA filter leak scan (single HEPA unit) ■ Compatible with comprehensive efficiency measurement of HEPA filters (both single and double HEPA units) ■ HEPA replacement via bug-out (replacement of HEPA after cleaning) *For more details, please refer to the PDF document or feel free to contact us.

  • Clean Room

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Package-type exhaust unit <negative pressure management>

Sterilize and remove dust from exhaust and intake with a HEPA filter! It can be turned into a negative pressure room while keeping the space clean.

To prevent hospital-acquired infections, it is desirable to create negative pressure in examination rooms and patient rooms. The "packaged exhaust unit" can be easily converted into a negative pressure room by simply installing it in existing spaces. In addition to allowing negative pressure adjustment through the exhaust side damper, it can also adjust pressure according to the size of the room. 【Features】 ■ Sterilizes and removes dust from exhaust and intake using HEPA filters ■ Can create a negative pressure room while keeping the area clean ■ Allows negative pressure adjustment via the exhaust side damper ■ Can adjust pressure according to the size of the room ■ Low noise type *Low speed: 40 dBA (measured in anechoic chamber) *For more details, please refer to the PDF document or feel free to contact us.

  • Welfare and medical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Package-type exhaust unit "PEU02-20"

As a measure against viral infections, we have adopted antibacterial coatings! The filter replacement indicator will notify you when it's time to replace it!

The 『PEU02-20』 is a packaged exhaust unit that can create a negative pressure room when installed in examination rooms, hospital rooms, etc. The air supplied and exhausted is filtered through a HEPA filter to capture dust and viruses. The thickness of the main unit has been reduced by 80mm compared to conventional products, making it slimmer. Additionally, the installation direction of the exhaust chamber box can be selected from left or right, and it features an antibacterial coating as a measure against viral infections. 【Features】 ■ The air supplied and exhausted is filtered through a HEPA filter to capture dust and viruses. ■ It can clean the indoor environment and create a negative pressure room. ■ The thickness of the main unit has been reduced by 80mm compared to conventional products, making it slimmer. ■ A filter replacement indicator alerts you when it’s time to change the filter. ■ The installation direction of the exhaust chamber box can be selected from left or right. *For more details, please refer to the PDF document or feel free to contact us.

  • Air conditioning equipment
  • Welfare and medical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration